usb

USB Firewire

(IM-110875)

USB Firewire
Technical sheet
Description
FireWire flex 2x2xAWG26-110+2xAWG22 FR-PUR black c(UR)us AWM
Application
for fixed installation and flexible application without compulsory guide using standard design, halogen free
Conductor
Stranded or extra fine stranded tinned copper wires
Data pairs: AWG24 (USB) AWG26 or AWG24 (FireWire)
Power supply cores: AWG20 (USB) AWG22 (FireWire)
Core numbers
6
Stranding
2x2xAWG26+2xAWG22
Section
AWG26, AWG22
Insulation
Data pairs: Polyolefin, green and white (USB), foam-skin polyolefin, red, green, orange and blue (FireWire)
Power supply cores: Special compound of polyvinylchloride (PVC), red and black (USB), white and black (FireWire)
Core identification
Data pairs: green and white (USB), red, green, orange and blue (FireWire)
Power supply cores: red and black (USB), white and black (FireWire)
1° shield/armouring
Plastic bonded aluminium tape or contuctive slide taping and braid of tinned copper wires
Inner jacket/tape
Slide taping or extruded covering (fast connect design)
2° shield/armouring
Plastic bonded aluminium tape (optional)
Outer jacket
PUR
Jacket colour
black similar to RAL 9005
Outer diameter mm.
6,8
Cu weight Kg/Km
34
Cable weight Kg/Km
64
Operating temperature
-40°C to +80°C fixed installation
-10°C to +70°C flexible application
Operating voltage
max. 250 V (peak value, not for connection to public mains)
Impedance
90 ohm ± 15% (USB)
110 ± 6 ohm (FireWire)
Resistance
max. 290.0 ohm / km (AWG26)
max. 181.8 ohm / km (AWG24)
max. 114.8 ohm / km (AWG22)
max. 71.6 ohm / km (AWG20)
Bending Radius
8 x cable diameter fixed installation
15 x cable diameter flexible application
Approvals / norms
c(UR)us recognition AWM style 21198 (80°C, 300V) according to UL 758, IEC 60811-2-1 Horizontal flame test (UL 2556)