Technical sheet
Description
DeviceNet™ 2xAWG18-120+2xAWG15 FRNC vT DESINA c(UL)us CMG
Application
for fixed installation and flexible application without compulsory guide as trunk cable using standard cable design, halogen-free
approvals: c(UL)us listing CMG according to UL 444, (UL) listing PLTC according to UL 13 in preparation
Conductor
Stranded tinned copper wires
Insulation
Data pairs: Foam-skin polyolefin Power supply cores: Polyolefin or PVC
Core identification
Data pairs: white and blue
Power supply cores: red and black
1° shield/armouring
Pair shieded: plastic bonded aluminium tape
Drain wire: stranded tinned copper wires AWG18 or AWG22
2° shield/armouring
Braid of tinned copper wires
Outer jacket
FRNC halogen free
Jacket colour
Violet similar to RAL 4001
Operating temperature
-40°C / +80°C fixed installation (PVC)
-25°C/+80° C fixed installation (FRNC)
-10° C/ +70° C pflexible installation
Operating voltage
max. 300 v (peak value, not for connection to public mains)
Resistance
max. 181.8 ohm / km (AWG24)
max. 114.8 ohm / km (AWG22)
max. 71.6 ohm / km (AWG20)
max. 45.4 ohm / km (AWG18)
max. 22.6 ohm / km (AWG15)
Bending Radius
5 x cable diameter fixed installation
10 x cable diameter flexible application
Approvals / norms
c(UL)us listing CMG according to UL 444, (UL) listing PLTC according to UL 13 in preparation