profinet

PROFINET 2 pair versions

(IM-130180)

PROFINET 2 COPPIE
Technical sheet
Description
PROFINET Cabinet Cable Cat.5e 2x2xAWG24-100 FRNC GN c(UR)us AWM
Application
For flexible application without compulsory guide using standard cable design
Conductor
Solid bare copper wire (Type A), 7-stranded tinned copper wires AWG22 (Type B) or 7-stranded tinned copper wires AWG24 (Cabinet Cable) (data pairs), power supply cores 0.34 mm² or 1.5 mm²
Core numbers
4
Section
AWG24
Insulation
Data pairs: Polyolefin, foam-skin polyolefin or fluorinated ethylene propylene (FEP) (white, yellow, blue and orange) Power supply cores: Polyolefin or special compound of polyvinylchloride (PvC) (core identification in accordance with DIN vDE 0293 – coloured or continuously numbered)
Core identification
white,yellow, blue and orange power supply: DIN 0293 coloured or continuously numbered
1° shield/armouring
Plastic bonded aluminium tape
Inner jacket/tape
Plastic tape (fast connect design with additional extruded covering)
2° shield/armouring
Braid of tinned copper wires
Outer jacket
FRNC
Jacket colour
green similar to RAL 6018
Outer diameter mm.
5,2
Cu weight Kg/Km
22
Cable weight Kg/Km
39
Operating temperature
-40°C to +80°C fixed installation
-25°C to +80°C fixed installation (FRNC)
-50°C to +180°C (short time use 205°C) fixed installation (FEP)
-10°C to +70°C flexible application (only flexible designs)
-30°C to +70°C flexible application (PUR)
Operating voltage
max. 125 v (peak value, not for connection to public mains)
Impedance
nom. 100 ohm according to IEC 61156-5 (AWG22) or IEC 61156-6 (AWG24)
Resistance
max. 115.0 ohm / km (AWG22) max. 181.8 ohm / km (AWG24) max. 115.0 ohm / km (power supply 0.34 mm²) max. 26.6 ohm / km (power supply 1.5 mm²)
Nominal capacity
nom 48 nF/km
Bending Radius
10 x cable diameter fixed installation
15 x cable diameter flexible application (only flexible designs)
Approvals / norms
c(UR)us recognition AWM style 21282 (80°C, 150v) according to UL 758
in preparation
Flame resistance: Horizontal flame test (UL 2556)