spiral cords

SPIRAL EXTENSIBLE CABLES IM06S

(IM06S-4X2X12-***)

SPIRAL CABLES IM06S
Technical sheet
Description
PUR Spiral Hybrid Shielded Cables with Medium Extension - mmq. 0,22 ---> 1,00
Cable type
Multicore shielded cable for signalling oil resistant,UL-CSA standard for dynamic laying
Conductor
Extra fine copper stranding according to VDE 0295 cl. 5/6
Insulation
PE or PP according to standard UL-CSA
Core identification
Different colors
Shield
Tinned copper braid covering >= 85%
Outer jacket
Polyurethane according to standard UL-CSA
Operating temperature
-30°C +80°C
Operating Voltage
sez. 0,09 - 0,14: 30V / 0,25 - 0,34: 300V
Test voltage
sez. 0,14: 500V / 0,25 - 0,34: 1500V
Approvals/norms
sez. 0,09 -0,14: 80°C 30V / 0,25 - 0,34: 80°C 300V
serie RE 1-3
UL VW-1 - IEC 60332.1 - EN 50265.2.1
Halogen free
VDE 0281 PAR I - VDE 0472 part 803 A/B - UL OIL RES.I - CNOMO E.03.40.150
Formation
4 x 2 x 0,25 + 2 x 1
Coil cord lenght resting from mm. to mm.
100 ---> 2000
Cable Ø mm. approx.
8,8
Spiral Ø mm. approx.
31,60
Jacket colour
arancio / orange