dynamic laying

UNIPOWERFLEX H PM UL MTW

(0301EBWA5XRNE)

UNIPOWERFLEX H PM UL MTW
Technical sheet
Description
UNIPOWERFLEX H PM UL MTW
Application
Power supply shielded conductor oil resist. cables UL-CSA and MTW approved, for dynamic laying max 180 m/min
Conductor
Flexible cond. complying with: NFC 32012 cl. 6 CEI 20-29 cl. 6, IEC 228 cl. 6, VDE 0295 cL. 6
Section
1 x 150
Insulation
Thermoplastic compound
Core identification
Speciale compound complying type OFS black colour
1° shield/armouring
Tinned copper braid covering >=80%
Outer jacket
Speciale compound complying type OFS black colour
Outer diameter mm.
28,2
Cu weight Kg/Km
1710
Operating temperature
–15° + 80°C for dynamic laying
Operating voltage
1000 V UL
Test voltage
4000 V
Resistance
100 Mohm
Km
Bending Radius
10 x cablendiameter for dynamic laying
Speed
180 m/min.
Acceleration
10 m/sec2
Approvals / norms
IEC 60332.3-24 cat. C
IEC 60332.1
VDE 0472 Parte 803/B UL 1581 CEI EN60811
CNOMO E 03.04.150N - 46-013
UL 758 AWM 80°C-1000V
OEM Standard
13EBW A5X 01R N8